Orenco Systems: Monitoring and Control Devices - MVP Control Panels - SSF

MVP SSF's

S1PTRO / DAX1PTRO / SSF's / MVP Case Study
/ MVP Video / How-To-Select Chart

MVP Sand Filter Control Panels are ideal for timed dosing in linked pump systems, where one panel controls two pumps in separate locations. "MVP SSF" panels include a "high level alarm lock-out" in which a high level alarm in the downstream location prevents the upstream pump from operating until the alarm situation is corrected. In addition, "MVP-SSF" panels include an easy-to-use, programmable logic unit that incorporates many timing and logic functions (e.g., normal timer, override timer), such as multiple timing intervals to adjust for changing flow conditions. When an alarm condition is reached, a minimum number of override cycles can be set to allow tank levels to drop, thus eliminating nuisance alarms. And as with all MVPs, elapsed time meters and counters are built right in.


 

Home ] [ Distributor Locator ] [ Contacting Orenco ] [ Site Map ] [ Search ]
Product Catalog ] [ Document Library ] [ Videos ]
Fiberglass Tanks ] [ Effluent Pumping Systems ] [ Advanced Treatment Systems ]
Community Collection Systems ] [ Wastewater Control Panels ]
About Orenco ] [ Information and Training ] [ New Products ]

Copyright © 2007 by Orenco Systems, Inc. Terms of Service
If you have questions or suggestions about the development or technology of this Web site, contact our Webmaster at webmaster@orenco.com. If you need information about Orenco Systems' products or services, contact Orenco.

This Web site has been optimized for the following browsers/settings:
Microsoft Internet Explorer version 6.0, at 800 x 600 resolution.